{"id":24663,"date":"2018-12-25T10:10:07","date_gmt":"2018-12-25T10:10:07","guid":{"rendered":"http:\/\/biomedpharmajournal.org\/?p=24663"},"modified":"2020-04-24T05:32:59","modified_gmt":"2020-04-24T05:32:59","slug":"comparing-the-shear-bond-strength-with-acrylic-teeth-hardness-surface-roughness-and-cost-benefit-of-three-different-denture-base-materials","status":"publish","type":"post","link":"https:\/\/biomedpharmajournal.org\/staging\/vol11no4\/comparing-the-shear-bond-strength-with-acrylic-teeth-hardness-surface-roughness-and-cost-benefit-of-three-different-denture-base-materials\/","title":{"rendered":"Comparing the Shear Bond Strength with Acrylic Teeth, Hardness, Surface Roughness and Cost-Benefit of Three Different  Denture Base Materials"},"content":{"rendered":"<p><strong>Introduction<\/strong><\/p>\n<p>The recent few years\u2019 have revealed huge developments in the science of biomaterials which is widely participate in the increasing human beings\u2019 life expectation. Polymeric materials are vastly utilized in complete and partial dentures fabrication.<sup>1<\/sup>Although, dental implants have received large attention with a high successful rate for the treatment of completely and partially edentulous conditions, dentures stayed the most popular choice for prosthetic treatment (Alla et al., 2015).<sup>2<\/sup><\/p>\n<p>In 1937, Poly methyl methacrylate (PMMA) was discovered by Dr. Walter Wright after he published the results of his clinical evaluation of PMMA which was known earlier as Vermonter.<sup>3<\/sup>\u00a0Alla et al., in their study in (2013), found that PMMA has the superior and the most satisfactory properties over all other denture base materials.<sup>4\u00a0<\/sup>It is a pure and colorless polymer of methyl methacrylate (MMA) with a chemical formula of (C5H8O2) n. Hypersensitivity and intolerance to the MMA monomer by patients as well as the medical team and the limitations in its properties, led to the development of several new materials such as (polycarbonate (PC), Polyamide (PA) and other) and inventing new processing techniques to overcome PMMA shortages.<sup>5,6<\/sup><\/p>\n<p>Many thermoplastic resins are used in dentistry, such as acetyl resins, PC resins (belonging to the group of polyester resins), polyamides (nylons) and acrylic resins.<sup>7<\/sup>\u00a0The utilization of these resins have greatly increased in the recent decade. The technique used is based on plasticizing the material and only thermal processing is used without any chemical reaction.<sup>8<\/sup>\u00a0Successful changes of the chemical composition and the ability to injected molding the present thermoplastic materials make them suitable materials for the fabrication of removable partial dentures which eliminate the metallic parts totally or partially, that lead to the formation of what so-called \u201cmetal-free removable partial dentures\u201d.<sup>9<\/sup><\/p>\n<p>Polycarbonate (PC) was introduced to the market in 1953 by Bayer in Germany and General Electric in the US, under trade name (LEXAN), independently. After that, many companies in America, Japan and in Europe started the production of it.<sup>10\u00a0<\/sup>The molecule of PC is consisted of a bisphenol A (BPA) and a carbonate group. The BPA have two aromatic rings; these aromatic rings give PC stiff backbone. PC contains, in its back bone which contains large aromatic content of phenyl groups\u00a0(benzene ring), also has moderately large pendent oxygen and hydrogen groups. These groups allow the tangle with the nearby polymer chains, and the formation of hydrogen bond. All these factors will lead to improve the resistance to intermolecular movements.<strong>\u00a0<\/strong><\/p>\n<p><strong>Materials and Methods<\/strong><\/p>\n<p><strong>Shear Bond Strength<\/strong><\/p>\n<p>It is believed, from clinical point of view, that testing the shear bond strength is to be more acceptable than the tensile test because the stress is uniformly distributed during shear testing. Unfortunately, it is technique sensitive.<sup>11<\/sup><\/p>\n<p>Hamanaka et al. in (2013)<sup>12\u00a0<\/sup>studied the shear bond strength between PMMA and different thermoplastic materials and found that polyamide difficult to bond to PMMA while PC is easier to bond with PMMA. While Khalaf et al. in (2011)<sup>13\u00a0<\/sup>studied the bonding strength between the acrylic teeth and PMMA and other thermoplastic denture base materials and reported that wetting the ridge laps of the teeth can increase the bond strength of acrylic teeth and the conventional heat cured resin while the other thermoplastic denture base materials need some mechanical means to improve the bond strength.<\/p>\n<p><strong>Hardness<\/strong><\/p>\n<p>It is related to many properties such as ductility, plasticity, strength, toughness, strain, viscosity, stiffness and viscoelasticity.<sup>14<\/sup><\/p>\n<p>Han in (2009)<sup>15\u00a0<\/sup>studied the effect of the molecular structure of polymer on the surface resistance to indentation and he found that polymers with large aromatic backbone such as PC will be easier to be penetrated by indenter. Also Bahrani et al. in (2012)<sup>16\u00a0<\/sup>compared two types of PMMA (heat and cold cured) that processed by different techniques and reported a non-significant change in the hardness of the two materials.<sup>\u00a0\u00a0<\/sup><\/p>\n<p><strong>Surface Roughness<\/strong><\/p>\n<p>It considered as a predictor for the material behaviors and performance, as surface irregularities will act as a nucleation sites for cracks or corrosion, but they will allow and improve adhesion.<sup>17<\/sup><\/p>\n<p>According to Jagger et al. in (2002),<sup>18\u00a0<\/sup>surface roughness of the dentures considered as an important clinical factor that affect the denture cleaning and enhance staining and plaque accumulation. Surface irregularities of the denture hander denture cleaning, reduce the efficiency of the cleaning agent, and act as a site for plaque and microorganism retention.<\/p>\n<p><strong>Cost\u2013Benefit Analysis (CBA)<\/strong><\/p>\n<p>The cost is \u201cAn amount that needed to be paid or given up in order to get something\u201d. It is a financial estimation of many variables including material, resources, effort, utilities and time expanded, hazard, and chance of forgone in fabrication and delivery of a good or service. Not all costs are expenses. but all expenses are costs. Cost considered as one of the major factor affecting the selection of a material, as in some cases material with impressive properties is limitedly used because of its high expense.<sup>1\u00a0<\/sup>Increase the expenses of the treatment will affect the selection of the treatment plan and in turn the overall treatment results.<\/p>\n<p>The cost analysis is analytical and systematic procedure by comparing the costs and benefits\u00a0in assessing the desirability of a material or program that is of a social nature.<sup>19\u00a0<\/sup>The theory of cost-benefit analysis is conducive to the understanding by providing an official illustration of the subject and investigating the theoretical basis of some techniques that became the agreed tools of making decision around the world. It is aimed to give a consistent process for decisions evaluation in regarding to their outcome.<sup>20<\/sup><\/p>\n<p>This study investigated some mechanical properties of polycarbonate (A) (Extra Rigid M10 polymer. Deflex, Argentina), injectable acrylic (B) (ACRILITO Injectable acrylic. Deflex, Argentina) and conventional heat cured acrylic (C) (MR.Dental, MEADWAY, England) and measuring the cost\/ benefit of these materials. A total of ninety specimens were fabricated according to manufacturer\u2019s instructions. Thirteen cylinder shaped specimens, into which acrylic teeth were attached, were fabricated to test the shear bond strength. They were divided into (3) groups each contains (10) specimens according to the material used. Another sixty bar shaped specimens were fabricated and divided into (2) groups according to the conducted tests i.e. surface roughness, and shore D hardness, each containing (30) specimens according to the material used (where n=10). The dimensions of the those for shear bond strength were (12 mm diameter x35 mm length)<sup>21\u00a0<\/sup>\u00a0while those for the surface roughness and shore D hardness tests were (65 x 10 x 2.5 \u00b1 0.1 mm).<sup>22<\/sup><\/p>\n<p>The laser-cutting machine was used to prepare the custom-made acrylic pattern and bar pattern (Glass-look acrylic, Clairvaux les Lacsrance, France) after being designed by (Auto CAD 2015) computer software.<\/p>\n<p>For shear bond strength a custom made acrylic pattern and copper tube was designed to fabricate the specimens molds as following:<\/p>\n<p><strong>Acrylic Pattern<\/strong><\/p>\n<p>Two custom made acrylic cylinders were made with dimension of (71 mm diameter and 6 mm thickness) with a hole in the center (24.5 mm diameter) for the insertion of custom made copper tube. A slot was cut through the cylinder at one side with dimension (6 x 11 x 6mm width, length and thickness respectively), to accommodate a custom made (7) shaped bar with 45<sup>0<\/sup> angle end. These cylinders were used as a holder for copper tube mold and (7) shaped bar.<\/p>\n<p>A custom made seven (7) shaped bar of (9.75 x 62.25 x 5.75 mm width, length and thickness in respectively) dimension regarding its long arm with 45<sup>0<\/sup>angled end for short arm with dimension of 9.75mm width x 25.87mm length for superior part and 5.75mm width x 15.7mm length for inferior part, used for accurate positioning of acrylic teeth<sup>23\u00a0<\/sup>The custom made acrylic cylinders and seven (7) shaped bar are depicted in (Figure 1).<\/p>\n<table style=\"width: 70%;\" border=\"1\" cellpadding=\"5\">\n<tbody>\n<tr>\n<td><img decoding=\"async\" class=\"alignnone size-thumbnail wp-image-24664\" src=\"https:\/\/biomedpharmajournal.org\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig1-150x150.jpg\" alt=\"Figure 1: acrylic pattern parts with dimension\" width=\"150\" height=\"150\" srcset=\"https:\/\/biomedpharmajournal.org\/staging\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig1-150x150.jpg 150w, https:\/\/biomedpharmajournal.org\/staging\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig1-256x256.jpg 256w, https:\/\/biomedpharmajournal.org\/staging\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig1.jpg 528w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/td>\n<td><strong>Figure 1:\u00a0 acrylic pattern parts with dimension<\/strong><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/biomedpharmajournal.org\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig1.jpg\" target=\"_blank\">Click here to view figure<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Copper Tube<\/strong><\/p>\n<p>A turning machine used to prepare a custom made copper tubes molds which is used for prepare test specimen&#8217;s wax pattern, with (24.5mm diameter) outer dimension, (14 mm diameter) inner hole dimension and (35 mm) length.<\/p>\n<p>Left maxillary central incisor acrylic teeth (BETASTAR teeth, BETA DENT), were used in preparation of test specimens, with no modification on the tooth surface and without addition of any mechanical means.<sup>23<\/sup>\u00a0Mold parts of shear bond with acrylic teeth test are shown in (Figure 2).<\/p>\n<table style=\"width: 70%;\" border=\"1\" cellpadding=\"5\">\n<tbody>\n<tr>\n<td><img decoding=\"async\" class=\"alignnone size-thumbnail wp-image-24665\" src=\"https:\/\/biomedpharmajournal.org\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig2-150x150.jpg\" alt=\"Figure 2: Shear bond with acrylic teeth test Mold Parts A: complete molds parts; B: side view of the molds; C: angled view of the molds\" width=\"150\" height=\"150\" srcset=\"https:\/\/biomedpharmajournal.org\/staging\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig2-150x150.jpg 150w, https:\/\/biomedpharmajournal.org\/staging\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig2.jpg 628w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/td>\n<td><strong>Figure 2:\u00a0<\/strong><strong>Shear bond with acrylic teeth test Mold Parts<\/strong> <strong>A: complete molds parts; B: side<\/strong><strong> view of the molds<\/strong><strong>; C: <\/strong><strong>angled view of the molds.<\/strong><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/biomedpharmajournal.org\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig2.jpg\" target=\"_blank\">Click here to View figure<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>The traditional complete dentures processing technique was followed during the mold preparation. The acrylic patterns and wax pattern (for shear bond test except the acrylic teeth) were first coated with separating medium (Isodent Gypsum separating solution) and left to be dry. Dental stone (Kimberlit Extra Hard High Density Die Stone) mixed according to the manufacturer\u2019s instructions and filled the lower part of the metal flask. Approximately one-half of the acrylic patterns were invested in dental stone in order to make a mark representing half of acrylic patterns depth after been measured by vernier. After dental stone completely set, a second layer of the separating medium was applied and left to dry. The upper part of the flask was properly positioned and filled with stone. The same procedure was used in fabricating thermoplastic specimens (polycarbonate and injectable acrylic) with an additional step where wax tubes was attached to the acrylic pattern to allow the injection of the material. Wax elimination process done to remove the wax pattern by immersed the flask into hot water bath of 100<sup>o <\/sup>C for 10 min. Packing and curing of the heat cured specimens was performed according to ADA 1999<sup>22\u00a0<\/sup>(Figure 3).<\/p>\n<table style=\"width: 70%;\" border=\"1\" cellpadding=\"5\">\n<tbody>\n<tr>\n<td><img decoding=\"async\" class=\"alignnone size-thumbnail wp-image-24666\" src=\"https:\/\/biomedpharmajournal.org\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig3-150x150.jpg\" alt=\"Click here to View figure\" width=\"150\" height=\"150\" srcset=\"https:\/\/biomedpharmajournal.org\/staging\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig3-150x150.jpg 150w, https:\/\/biomedpharmajournal.org\/staging\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig3.jpg 661w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/td>\n<td><strong>Figure 3: <\/strong><strong>Fabrication of the molds; A: heat cured acrylic molds; B: polycarbonate and injectable acrylic molds; C: shear bond strength mold for heat cured acrylic; D: molds for shear bond strength (polycarbonate and injectable acrylic).<\/strong><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/biomedpharmajournal.org\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig3.jpg\" target=\"_blank\">Click here to View figure<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>The injection of the thermoplastic resins was done according to manufacturer\u2019s instruction under (5-7 Bar) for (15 min) (for Polycarbonate, the injection temperature is (305<sup>o<\/sup>C \u00b1 10<sup>o<\/sup>C) while the injectable acrylic temperature is (265<sup>o<\/sup>C \u00b1 10<sup>o<\/sup>C)) . Finally, each test specimens group was gathered and placed in plastic containers, filled with distilled water were placed in incubator for 48 hours at 37<sup>o<\/sup>C ).<sup>22<\/sup><\/p>\n<p>Shear bond strength test was conducted according to Japanese Standard for acrylic teeth by using a universal instron testing machine, the specimen was positioned in custom made copper tube and inserted inside custom made aluminum holder for teeth bonding and screws passed\u00a0 through the holder and copper tube till it came in contact with specimen to insure the specimen was fixed in position during the test , with 50 Kg (full scale), and the load was directed by wedge shaped end metal stud \u00a0to the incisal one third of the tooth in order to have the best simulation of the clinical forces on the maxillary central incisor at a crosshead speed of 0.6mm min and a load cell range of 1000 N until fracture occurred, as seen in (Figure 4).<\/p>\n<table style=\"width: 70%;\" border=\"1\" cellpadding=\"5\">\n<tbody>\n<tr>\n<td>\u00a0<img decoding=\"async\" class=\"alignnone size-thumbnail wp-image-24667\" src=\"https:\/\/biomedpharmajournal.org\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig4-150x150.jpg\" alt=\"Figure 4: Shear Bond Strength testing; A: specimen positioned in the clamp; B: close picture of the testing; C: polycarbonate specimens after testing; D: heat cured acrylic specimens after testing; E: injectable acrylic specimens after testing; F and G: custom made aluminum holder\" width=\"150\" height=\"150\" srcset=\"https:\/\/biomedpharmajournal.org\/staging\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig4-150x150.jpg 150w, https:\/\/biomedpharmajournal.org\/staging\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig4-256x256.jpg 256w, https:\/\/biomedpharmajournal.org\/staging\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig4.jpg 655w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/td>\n<td><strong>Figure 4: Shear Bond Strength testing; A: specimen positioned in the clamp; B: close picture of the testing; C: polycarbonate specimens after testing; D: heat cured acrylic specimens after testing; E: injectable acrylic specimens after testing; F and G: <\/strong><strong>custom made aluminum holder.<\/strong><\/p>\n<p><a href=\"http:\/\/biomedpharmajournal.org\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig4.jpg\" target=\"_blank\">Click here to View figure<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>For Hardness test, Shore D durometer was used (according to ASTM D2240-03 standard).<sup>24<\/sup>\u00a0For each specimen, five points were marked with 6 mm distance apart from each other. The hardness value was calculated as the average of these 5 reading. Shore D durometer was placed vertically over flat sample supported by rigid, flat base, the readings were taken after 3 second of stable contact over the specimen when the indenter was pressed down firmly and quickly on to record the maximum reading. The reading was taken directly from the reading scale, as seen in (Figure 5).<\/p>\n<table style=\"width: 70%;\" border=\"1\" cellpadding=\"5\">\n<tbody>\n<tr>\n<td>\u00a0<img decoding=\"async\" class=\"alignnone size-thumbnail wp-image-24668\" src=\"https:\/\/biomedpharmajournal.org\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig5-150x150.jpg\" alt=\"Figure 5: Shore D. hardness testing. A: Shore D. hardness testing device; B: the specimen placed under the device; C: specimens for Shore D. hardness test (red + polycarbonate, black + heat cured acrylic, and blue + injectable acrylic specimens)\" width=\"150\" height=\"150\" srcset=\"https:\/\/biomedpharmajournal.org\/staging\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig5-150x150.jpg 150w, https:\/\/biomedpharmajournal.org\/staging\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig5-256x256.jpg 256w, https:\/\/biomedpharmajournal.org\/staging\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig5.jpg 596w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/td>\n<td><strong>Figure 5: Shore D. hardness testing. A: Shore D. hardness testing device; B: the specimen placed under the device; C: specimens for Shore D. hardness test (red + polycarbonate, black + heat cured acrylic, and blue + injectable acrylic specimens).<\/strong><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/biomedpharmajournal.org\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig5.jpg\" target=\"_blank\">Click here to View figure<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>For surface roughness measurement, a portable digital roughness tester (Profilometer) with 0.001 \u03bcm accuracy was used. The stylus just contacts the surface of the specimen in three different points across the specimen to have 3 readings from each specimen, the specimen was placed on stable and rigid surface and allowed the stylus to touches the first point, then it should move across the specimen surface for 11 mm, the reading appears in a spontaneous manner on the digital scale. Later on, mean value of the three readings was reported as roughness value, as seen in (Figure 6).<\/p>\n<table style=\"width: 70%;\" border=\"1\" cellpadding=\"5\">\n<tbody>\n<tr>\n<td>\u00a0<img decoding=\"async\" class=\"alignnone size-thumbnail wp-image-24669\" src=\"https:\/\/biomedpharmajournal.org\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig6-150x150.jpg\" alt=\"Figure 6: Surface roughness testing. A: Profilometer; B&amp; C: specimen testing at different points.\" width=\"150\" height=\"150\" srcset=\"https:\/\/biomedpharmajournal.org\/staging\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig6-150x150.jpg 150w, https:\/\/biomedpharmajournal.org\/staging\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig6-256x256.jpg 256w, https:\/\/biomedpharmajournal.org\/staging\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig6.jpg 636w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/td>\n<td><strong>Figure 6: Surface roughness testing. A: Profilometer; B&amp; C: specimen testing at different points.<\/strong><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/biomedpharmajournal.org\/wp-content\/uploads\/2018\/12\/Vol11No4_Com_Isa_fig6.jpg\" target=\"_blank\">Click here to View figure<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Results<\/strong><\/p>\n<p>Shear bond with acrylic teeth, shore D hardness, surface roughness and cost of specimens:<\/p>\n<p>Descriptive statistics, One-way ANOVA and the LSD analysis were presented in tables 1-4.<\/p>\n<p>Regarding the shear bond strength test results, there was a highly significant difference (p&lt;0.01) between all the experimental groups. The heat cured acrylic (A) showed the highest mean value (516.1) followed by the injectable acrylic (B) with (329.9) while the lowest mean value was for the polycarbonate (C) with only (180.1) (Table 1).<\/p>\n<p><strong>Table 1:<\/strong><strong> Descriptive statistics, One-way ANOVA and LSD of shear bond strength test<\/strong><strong>.<\/strong><\/p>\n<table style=\"width: 95%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"4\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\" colspan=\"4\" width=\"196\"><strong>LSD<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"57\">&nbsp;<\/p>\n<p><strong>P- value<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"85\">&nbsp;<\/p>\n<p><strong>ANOVA F- test<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"95\"><strong>C<\/strong><\/p>\n<p><strong>(injectable acrylic)<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"94\"><strong>B<\/strong><\/p>\n<p><strong>( Poly-carbonate)<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"76\"><strong>A<\/strong><\/p>\n<p><strong>(heat cured acrylic)<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"57\"><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"45\"><strong>Sig.<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"57\"><strong>P. value<\/strong><\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"95\"><strong>Compared groups<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"45\">HS<\/td>\n<td style=\"text-align: center;\" width=\"57\">0.000<\/td>\n<td style=\"text-align: center;\" width=\"47\">B<\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"47\">&nbsp;<\/p>\n<p>A<\/td>\n<td style=\"text-align: center;\" rowspan=\"5\" width=\"57\">0.000<\/p>\n<p>HS<\/td>\n<td style=\"text-align: center;\" rowspan=\"5\" width=\"85\">1105.74<\/td>\n<td style=\"text-align: center;\" width=\"95\">10<\/td>\n<td style=\"text-align: center;\" width=\"94\">10<\/td>\n<td style=\"text-align: center;\" width=\"76\">10<\/td>\n<td style=\"text-align: center;\" width=\"57\">N<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"45\">HS<\/td>\n<td style=\"text-align: center;\" width=\"57\">0.000<\/td>\n<td style=\"text-align: center;\" width=\"47\">C<\/td>\n<td style=\"text-align: center;\" width=\"95\">329.9<\/td>\n<td style=\"text-align: center;\" width=\"94\">180.1<\/td>\n<td style=\"text-align: center;\" width=\"76\">516.1<\/td>\n<td style=\"text-align: center;\" width=\"57\">Mean<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"45\">HS<\/td>\n<td style=\"text-align: center;\" width=\"57\">0.000<\/td>\n<td style=\"text-align: center;\" width=\"47\">C<\/td>\n<td style=\"text-align: center;\" width=\"47\">B<\/td>\n<td style=\"text-align: center;\" width=\"95\">20.95<\/td>\n<td style=\"text-align: center;\" width=\"94\">13.64<\/td>\n<td style=\"text-align: center;\" width=\"76\">11.976<\/td>\n<td style=\"text-align: center;\" width=\"57\">SD<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"4\" rowspan=\"2\" width=\"196\"><\/td>\n<td style=\"text-align: center;\" width=\"95\">314.9<\/td>\n<td style=\"text-align: center;\" width=\"94\">170.34<\/td>\n<td style=\"text-align: center;\" width=\"76\">507.53<\/td>\n<td style=\"text-align: center;\" width=\"57\">Min.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"95\">344.8<\/td>\n<td style=\"text-align: center;\" width=\"94\">189.85<\/td>\n<td style=\"text-align: center;\" width=\"76\">424.66<\/td>\n<td style=\"text-align: center;\" width=\"57\">Max.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>As for the Shore D hardness test results, there was a highly significant difference (p&lt;0.01) between (B) and (A, C) groups, while no significant difference (p\u02c30.05) between (A and B) groups was found. The injectable acrylic group (B) showed the highest mean value (91.96) followed by the heat cured acrylic (A) with (91.5) while the lowest mean value was for the polycarbonate (C) with only (82.94) (Table 2).<\/p>\n<p><strong>Table 2:<\/strong><strong> Descriptive statistics, One-way ANOVA and LSD of shore D hardness test<\/strong><\/p>\n<table style=\"width: 95%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"4\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\" colspan=\"4\" width=\"196\"><strong>LSD<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"57\">&nbsp;<\/p>\n<p><strong>P- value<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"85\">&nbsp;<\/p>\n<p><strong>ANOVA F- test<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"95\"><strong>C<\/strong><\/p>\n<p><strong>(injectable acrylic)<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"94\"><strong>B<\/strong><\/p>\n<p><strong>( Poly-carbonate)<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"76\"><strong>A<\/strong><\/p>\n<p><strong>(heat cured acrylic)<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"57\"><strong>\u00a0<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"45\"><strong>Sig.<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"57\"><strong>P. value<\/strong><\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"95\"><strong>Compared groups<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"45\">HS<\/td>\n<td style=\"text-align: center;\" width=\"57\">0.000<\/td>\n<td style=\"text-align: center;\" width=\"47\">B<\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"47\">&nbsp;<\/p>\n<p>A<\/td>\n<td style=\"text-align: center;\" rowspan=\"5\" width=\"57\">0.000<\/p>\n<p>HS<\/td>\n<td style=\"text-align: center;\" rowspan=\"5\" width=\"85\">75.536<\/td>\n<td style=\"text-align: center;\" width=\"95\">10<\/td>\n<td style=\"text-align: center;\" width=\"94\">10<\/td>\n<td style=\"text-align: center;\" width=\"76\">10<\/td>\n<td style=\"text-align: center;\" width=\"57\">N<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"45\">NS<\/td>\n<td style=\"text-align: center;\" width=\"57\">0.582<\/td>\n<td style=\"text-align: center;\" width=\"47\">C<\/td>\n<td style=\"text-align: center;\" width=\"95\">91.96<\/td>\n<td style=\"text-align: center;\" width=\"94\">82.94<\/td>\n<td style=\"text-align: center;\" width=\"76\">91.5<\/td>\n<td style=\"text-align: center;\" width=\"57\">Mean<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"45\">HS<\/td>\n<td style=\"text-align: center;\" width=\"57\">0.000<\/td>\n<td style=\"text-align: center;\" width=\"47\">C<\/td>\n<td style=\"text-align: center;\" width=\"47\">B<\/td>\n<td style=\"text-align: center;\" width=\"95\">1.472<\/td>\n<td style=\"text-align: center;\" width=\"94\">2.168<\/td>\n<td style=\"text-align: center;\" width=\"76\">1.838<\/td>\n<td style=\"text-align: center;\" width=\"57\">SD<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"4\" rowspan=\"2\" width=\"196\"><\/td>\n<td style=\"text-align: center;\" width=\"95\">90.2<\/td>\n<td style=\"text-align: center;\" width=\"94\">80.6<\/td>\n<td style=\"text-align: center;\" width=\"76\">87.6<\/td>\n<td style=\"text-align: center;\" width=\"57\">Min.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"95\">94.6<\/td>\n<td style=\"text-align: center;\" width=\"94\">87.8<\/td>\n<td style=\"text-align: center;\" width=\"76\">94.2<\/td>\n<td style=\"text-align: center;\" width=\"57\">Max.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>On the other hand, a highly significant difference (p&lt;0.01) was also noticed between all the experimental groups of the surface roughness test. The experimental group (B) showed highest mean value (0.317) followed by group (C) with (0.212) while the lowest mean value was for group (A) (0.103) (Table 3).<\/p>\n<p><strong>Table 3:<\/strong><strong> Descriptive statistics, One-way ANOVA and LSD of surface roughness test.<\/strong><\/p>\n<table style=\"width: 95%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"4\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\" colspan=\"4\" width=\"196\"><strong>LSD<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"57\">&nbsp;<\/p>\n<p><strong>P- value<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"85\">&nbsp;<\/p>\n<p><strong>ANOVA F- test<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"95\"><strong>C<\/strong><\/p>\n<p><strong>(injectable acrylic)<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"94\"><strong>B<\/strong><\/p>\n<p><strong>( Poly-carbonate)<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"76\"><strong>A<\/strong><\/p>\n<p><strong>(heat cured acrylic)<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"57\"><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"45\"><strong>Sig.<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"57\"><strong>P. value<\/strong><\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"95\"><strong>Compared groups<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"45\">HS<\/td>\n<td style=\"text-align: center;\" width=\"57\">0.000<\/td>\n<td style=\"text-align: center;\" width=\"47\">B<\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"47\">&nbsp;<\/p>\n<p>A<\/td>\n<td style=\"text-align: center;\" rowspan=\"5\" width=\"57\">0.000<\/p>\n<p>HS<\/td>\n<td style=\"text-align: center;\" rowspan=\"5\" width=\"85\">10062.53<\/td>\n<td style=\"text-align: center;\" width=\"95\">10<\/td>\n<td style=\"text-align: center;\" width=\"94\">10<\/td>\n<td style=\"text-align: center;\" width=\"76\">10<\/td>\n<td style=\"text-align: center;\" width=\"57\">N<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"45\">HS<\/td>\n<td style=\"text-align: center;\" width=\"57\">0.000<\/td>\n<td style=\"text-align: center;\" width=\"47\">C<\/td>\n<td style=\"text-align: center;\" width=\"95\">0.212<\/td>\n<td style=\"text-align: center;\" width=\"94\">0.317<\/td>\n<td style=\"text-align: center;\" width=\"76\">0.103<\/td>\n<td style=\"text-align: center;\" width=\"57\">Mean<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"45\">HS<\/td>\n<td style=\"text-align: center;\" width=\"57\">0.000<\/td>\n<td style=\"text-align: center;\" width=\"47\">C<\/td>\n<td style=\"text-align: center;\" width=\"47\">B<\/td>\n<td style=\"text-align: center;\" width=\"95\">0.001<\/td>\n<td style=\"text-align: center;\" width=\"94\">0.005<\/td>\n<td style=\"text-align: center;\" width=\"76\">0.001<\/td>\n<td style=\"text-align: center;\" width=\"57\">SD<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"4\" rowspan=\"2\" width=\"196\"><\/td>\n<td style=\"text-align: center;\" width=\"95\">0.210<\/td>\n<td style=\"text-align: center;\" width=\"94\">0.311<\/td>\n<td style=\"text-align: center;\" width=\"76\">0.101<\/td>\n<td style=\"text-align: center;\" width=\"57\">Min.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"95\">0.216<\/td>\n<td style=\"text-align: center;\" width=\"94\">0.327<\/td>\n<td style=\"text-align: center;\" width=\"76\">0.106<\/td>\n<td style=\"text-align: center;\" width=\"57\">Max.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>Finally, the results of the specimens\u2019 cost also indicate a highly significant difference (p&lt;0.01) between all the experimental groups. The experimental group (B) showed the highest mean value (10.022) followed by group (C) with (8.695) while the lowest mean value was for group (A) with (3.243) (Table 4).<\/p>\n<p><strong>\u00a0<\/strong><strong>Table 4:<\/strong><strong> Descriptive statistics, One-way ANOVA and LSD of coast in USD \/sample.<\/strong><\/p>\n<table style=\"width: 95%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"4\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\" colspan=\"4\" width=\"196\"><strong>LSD<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"57\">&nbsp;<\/p>\n<p><strong>P- value<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"85\">&nbsp;<\/p>\n<p><strong>ANOVA F- test<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"95\"><strong>C<\/strong><\/p>\n<p><strong>(injectable acrylic)<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"94\"><strong>B<\/strong><\/p>\n<p><strong>( Poly-carbonate)<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"76\"><strong>A<\/strong><\/p>\n<p><strong>(heat cured acrylic)<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"57\"><strong>\u00a0<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"45\"><strong>Sig.<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"57\"><strong>P. value<\/strong><\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"95\"><strong>Compared groups<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"45\">HS<\/td>\n<td style=\"text-align: center;\" width=\"57\">0.000<\/td>\n<td style=\"text-align: center;\" width=\"47\">B<\/td>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"47\">&nbsp;<\/p>\n<p>A<\/td>\n<td style=\"text-align: center;\" rowspan=\"5\" width=\"57\">0.000<\/p>\n<p>HS<\/td>\n<td style=\"text-align: center;\" rowspan=\"5\" width=\"85\">2898.158<\/td>\n<td style=\"text-align: center;\" width=\"95\">10<\/td>\n<td style=\"text-align: center;\" width=\"94\">10<\/td>\n<td style=\"text-align: center;\" width=\"76\">10<\/td>\n<td style=\"text-align: center;\" width=\"57\">N<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"45\">HS<\/td>\n<td style=\"text-align: center;\" width=\"57\">0.000<\/td>\n<td style=\"text-align: center;\" width=\"47\">C<\/td>\n<td style=\"text-align: center;\" width=\"95\">8.695<\/td>\n<td style=\"text-align: center;\" width=\"94\">10.022<\/td>\n<td style=\"text-align: center;\" width=\"76\">3.243<\/td>\n<td style=\"text-align: center;\" width=\"57\">Mean<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"45\">HS<\/td>\n<td style=\"text-align: center;\" width=\"57\">0.000<\/td>\n<td style=\"text-align: center;\" width=\"47\">C<\/td>\n<td style=\"text-align: center;\" width=\"47\">B<\/td>\n<td style=\"text-align: center;\" width=\"95\">0.193<\/td>\n<td style=\"text-align: center;\" width=\"94\">0.267<\/td>\n<td style=\"text-align: center;\" width=\"76\">0.157<\/td>\n<td style=\"text-align: center;\" width=\"57\">SD<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"4\" rowspan=\"2\" width=\"196\"><\/td>\n<td style=\"text-align: center;\" width=\"95\">8.30<\/td>\n<td style=\"text-align: center;\" width=\"94\">9.50<\/td>\n<td style=\"text-align: center;\" width=\"76\">3.00<\/td>\n<td style=\"text-align: center;\" width=\"57\">Min.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"95\">8.91<\/td>\n<td style=\"text-align: center;\" width=\"94\">10.50<\/td>\n<td style=\"text-align: center;\" width=\"76\">3.50<\/td>\n<td style=\"text-align: center;\" width=\"57\">Max.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Discussion<\/strong><\/p>\n<p><strong>Shear bond strength with acrylic teeth test <\/strong><\/p>\n<p>The experimental group (heat cured acrylic) showed the highest mean value followed by the (injectable acrylic), while the lowest mean value was for the (polycarbonate). This result may be contributed to the chemical bond formation between the heat cured acrylic and PMMA (acrylic teeth) as a result to the presence of free monomers and polymerization stage at which the acrylic teeth were placed as explained by Khalaf et al in (2011)<sup>13<\/sup><\/p>\n<p>While for injectable acrylic the presence of trace residual monomer after injection of melted acrylic that will contact the acrylic teeth at a high temperature above PMMA glass transition temperature, will lead to melting of acrylic teeth at contact side and formation of Vander Vaal bond with the acrylic tooth. The injectable acrylic is fully polymerized, the presence of trace residual monomer, and formation of Vander Vaal bond which is weaker bond, will reduce the strength of the bond with acrylic teeth, which explain the lower bonding strength than of that of heat cured acrylic.<sup>25,26<\/sup><\/p>\n<p>Whereas for polycarbonate, there will be some partial blending with PMMA (acrylic teeth), this could be due to that the melted polycarbonate will contact the acrylic teeth at a high temperature above PMMA glass transition temperature will lead to melting of acrylic teeth at contact side and allow to the blending between the polycarbonate and PMMA. This is not strong enough same as with PMMA but able to hold the tooth in position.<sup>27<\/sup>\u00a0Another highly accepted opinion is the formation of physical bond between polycarbonate and PMMA as result of high surface roughness of polycarbonate.<sup>28<\/sup><\/p>\n<p><strong>Shore D hardness test<\/strong><\/p>\n<p>Regarding the Shore D hardness test result, the (injectable acrylic) group showed highest mean value of hardness followed by the (heat cured acrylic), while the lowest mean value of hardness was for the (polycarbonate).<\/p>\n<p>Heat cured acrylic and injectable acrylic both are PMMA in their chemical structure and the change found in the processing technique have no significate effect on their hardness.<sup>16<\/sup>\u00a0A highly significant difference between polycarbonate and PMMA (heat cured acrylic and injectable acrylic) was noticed which could be due to the differences in their molecular structure which affect the molecular interaction force, Frank energy and friction force related to the depth of indentation which affect polymer hardness. When polymer is subjected to indentation by durometer tip, the area under the indenter will compress by the force on the surface of the polymer that cause polymer chains to be displaced and packed within the elastic and plastic limit of the polymer. The polymer resistance to indentation, explained by strain gradient formulation of elasto-plastic material,\u00a0 suggested that polycarbonate\u2019s\u00a0 aromatic rings\u00a0 show increase the surface hardness at initial indentation depth up to 20 um after that the harness decreased with increase the indentation depth as it has higher range of plastic deformity, while PMMA did not have any aromatic ring in their structure which may explain increase in hardness at smaller indentation depth related to it complex structure.<sup>15\u00a0<\/sup>Another possible explanation that chemical structure and polymer molecules arrangement differences have an effect on the bending stiffness of the polymer chain and overall effect on the frank elasticity of polymer.<sup>29\u00a0<\/sup>Polycarbonate chain has higher bending stiffness and more elasticity as a result of it molecular structure and chain network arrangement which make polycarbonate less resistance to indentation, while PMMA chain has lower bending stiffness and more rigidity as a result of it molecular structure and chain network arrangement.<sup>30,31\u00a0<\/sup>This also supported by the standard result of durometer scale of material hardness.<sup>24<\/sup><\/p>\n<p><strong>Surface Roughness Test<\/strong><\/p>\n<p>There were highly significant differences between all 3 experimental groups with the highest mean value for experimental group (polycarbonate) followed by the (injectable acrylic), while the lowest mean value was for the (heat cured acrylic). This may be due to that all the injected molded polymers (polycarbonate and injectable acrylic) will have higher surface roughness than heat cured acrylic before polishing.<sup>32<\/sup>\u00a0this increase in surface roughness may be contributed to the injection process. Melted material during the injection will roll into the smaller tube (sprue) until it reaches the mold cavities and during this fountain flow movement a small polymer nucleus site will form that will affect the surface quality of material which cause increase in the surface roughness of injected molded polymers. The surface roughness of the injected molded polymers (polycarbonate and injectable acrylic) could be affected by many factors include mold cavities, injection speed and pressure, melting temperature and melting flow rate of the polymer.<sup>33<\/sup><\/p>\n<p>In this study the mold cavities (same for all specimens), injection speed and pressure were fixed by manufactural instruction for both polycarbonate and injectable acrylic. The melting temperature and melting flow rate of the polymer are different as melting temperature (305<sup>o<\/sup> C for polycarbonate and 265<sup>o<\/sup> C for injectable acrylic according to manufactural instruction), and melting flow rate of the polymer (polycarbonate slower than that for injectable acrylic) as regarding the index of the fluidity of the plastic resin. The increase in melting temperature for polycarbonate to overcome it unique resistance to the change in temperature as it retains its mechanical properties at higher temperature up to 220<sup>o<\/sup> C not as PMMA so melting flow rate of the polymer will have more effect than the melting temperature, which supported the results of this study.<sup>10<\/sup><\/p>\n<p><strong>Cost-Benefit Test<\/strong><\/p>\n<p>There were highly significant differences between all 3 experimental groups with the highest mean value was for experimental group (polycarbonate) followed by the (injectable acrylic), while the lowest mean value was for the (heat cured acrylic). The results show that heat cured acrylic with lowest cost in compare with polycarbonate and injectable acrylic which is related to low cost of material with no need for expensive equipment\u2019s with better properties for the selected tests.<\/p>\n<p>As for the injectable material which has higher cost due to more expensive equipment\u2019s and techniques as well as higher material\u2019s price with lower properties for the selected tests.<\/p>\n<p><strong>Conclusions<\/strong><\/p>\n<p>The following conclusions were reached after taking into consideration the limitations of this study<\/p>\n<p>all injectable materials included in this study exhibit lower shear bond with acrylic teeth, and higher surface roughness in compared with heat cured acrylic.<\/p>\n<p>as for hardness there was no effect of different processing techniques of PMMA (heat cured and injectable acrylic) and have higher hardness in compared with Polycarbonate.<\/p>\n<p>All thermoplastic materials included in this study exhibited higher cost with lower properties for the selected tests.<strong>\u00a0<\/strong><\/p>\n<p><strong>Acknowledgements<\/strong><\/p>\n<p>This work was based to thesis submitted to the council of college of dentistry \/ Baghdad University as a partial fulfillment for the requirement for the degree of Master of Science in prosthodontics, 2018.<strong>\u00a0<\/strong><\/p>\n<p><strong>Conflict of Interests<\/strong><\/p>\n<p>The authors declare that there is no conflict of interests regarding the publication of this paper.<\/p>\n<p><strong>Funding Source<\/strong><\/p>\n<p>There is no funding\u00a0source.<\/p>\n<p><strong>References<\/strong><\/p>\n<ol>\n<li>Alsamydai M. J. Modern marketing strategy, Dar Alhamid for Publishing and distribution, Amman: Jordan. 2018<\/li>\n<li>Alla R. K., Swamy K. N., Vyas R. R and Konakanchi A. Conventional and contemporary polymers for the fabrication of denture prosthesis: part I \u2013 overview, composition and properties. <em>IJADS.<\/em>\u00a02015;1(4):82-89.<\/li>\n<li>PEYTON F. A. History of resins in dentistry. <em> Clin. North. Am.<\/em>\u00a01975;19(2):211-222.<\/li>\n<li>Alla R. K., Saijan S., Alluri V. R., Ginjupalli K and Upadhya N. Influence of fiber reinforcement on the properties of denture base Resins. <em> Biomater. Nano. Biotech.<\/em>\u00a02013;4(1):91-97.<br \/>\n<a href=\"https:\/\/doi.org\/10.4236\/jbnb.2013.41012\" target=\"_blank\">CrossRef<\/a><\/li>\n<li>J\u2019Obrien W. Dental materials and their selection. 3<sup>rd<\/sup> Michigan,US:Quintessence Publishing Co. Inc. 2013;74-89.<\/li>\n<li>Meng T. R Jr and Latta M. A. Physical properties of four acrylic denture base resins. <em> Contemp. Dent. Pract<\/em>. 2005;6(4):93-100.<\/li>\n<li>Negrutiu M., Sinescu C., Romanu M., Pop\u00a0 D And Lakatos S. Thermoplastic resins for flexible framework removable partial dentures. <em>TMJ.\u00a0<\/em>2005;55(3):295-299.<\/li>\n<li>Ardelean L., Bortun C., Podariu A and Rusu L. Thermoplastic composite material. InTech, 2012.<\/li>\n<li>Bortun C, Lakatos S, Sandu L, Negrutiu M and Ardelean L, Metal-free removable partial dentures made of thermoplastic materials. <em>TMJ.\u00a0<\/em>2006;56(1):80-88.<\/li>\n<li>Bozzano G., Dente M and Del Rosso R.\u00a0 Poly(bisphenol a carbonate) recycling: high pressure hydrolysis can be a convenient way, Material Recycling &#8211; Trends and Perspectives, Dr. Dimitris Achilias (Ed.), ISBN: 978-953-51-0327-1. In Tech.\u00a0 2012.<\/li>\n<li>Sulaiman S. A. Bonding strength between acrylic teeth and different types of acrylic denture base materials. M.Sc. Thesis, University of Baghdad. 2012.<\/li>\n<li>Hamanaka I., Shimizu H and Takahashi Y. Shear bond strength of an autopolymerizing repair resin to injection-molded thermoplastic denture base resins.\u00a0<em> Odontol. Scand<\/em>. 2013;71:1250\u20131254.<br \/>\n<a href=\"https:\/\/doi.org\/10.3109\/00016357.2012.757645\" target=\"_blank\">CrossRef<\/a><\/li>\n<li>Khalaf B. S., Abdulsahib A. J and Abass S. M. Bond strength of acrylic teeth to heat cure acrylic resin and thermoplastic denture base materials. <em>JKU.<\/em>\u00a02011;9(4):35-44.<\/li>\n<li>Wredenberg F and Larsson P. L. Scratch testing of metals and polymers: Experiments and numeric.\u00a0<em>Wear.<\/em>\u00a02009;266(1\u20132):76-83.<br \/>\n<a href=\"https:\/\/doi.org\/10.1016\/j.wear.2008.05.014\" target=\"_blank\">CrossRef<\/a><\/li>\n<li>Han C. S. Influence of the molecular structure on indentation size effect in polymers<em>. Mater. Sci. and Eng. A<\/em>. 2010;527(3):619\u2013624.<br \/>\n<a href=\"https:\/\/doi.org\/10.1016\/j.msea.2009.08.033\" target=\"_blank\">CrossRef<\/a><\/li>\n<li>Bahrani\u00a0 F., Safari\u00a0 A., Vojdani\u00a0 M and Karampoor G. Comparision of hardness and surface roughness of two denture bases polymerized by different methods. <em>World J. Dent<\/em>.\u00a0 2012;3(2):171-175.<br \/>\n<a href=\"https:\/\/doi.org\/10.5005\/jp-journals-10015-1151\" target=\"_blank\">CrossRef<\/a><\/li>\n<li>Hanaor D., Gan Y and Einav I. Static friction at fractal interfaces.<em>\u00a0Tribol. Int<\/em>. 2016;93:229-238.<br \/>\n<a href=\"https:\/\/doi.org\/10.1016\/j.triboint.2015.09.016\" target=\"_blank\">CrossRef<\/a><\/li>\n<li>Jagger R. G., Al-Athel M. S., Jagger D. C and Vowles R. W. Some variables influencing the bond strength between PMMA and a silicon denture lining material. <em> J. Prosthodont.\u00a0\u00a0<\/em>2002;15(1):55-58.<\/li>\n<li>Quah E and Mishan E. j.\u00a0 Coast- Benefit Analysis. 5<sup>th<\/sup>, Routledg: London. 2007.<\/li>\n<li>Dreze j and Stem N.\u00a0 Theory of coast-benefit analysis. Handbook of public economics.<em> Elsevier.<\/em> 1987;2:909-989.<\/li>\n<li>Al-Somaiday H. M., Ali M. M and Fatihallah A. A. Comparing impact strength and transverse flexure strength of three different denture base materials. <em> &amp; Pharmacol. J.\u00a0<\/em>\u00a02018;11(1):255-263.<br \/>\n<a href=\"https:\/\/doi.org\/10.13005\/bpj\/1370\" target=\"_blank\">CrossRef<\/a><\/li>\n<li>American Dental Association Specification No. 12 for denture base polymer guide to dental materials and devices, 7th edition, Chicago: Illiniois. 1999.<\/li>\n<li>Japan Science and Technology Agency Specification 6506: Acrylic resin teeth.Tokyo, Japan: JIST. 1989.<\/li>\n<li>ASTM standard Specification D2240-3. Test for Rubber Property-Durometer hardness. Barr Harbor, Unite State of America. 2003.<\/li>\n<li>Nicholson J. W<i>.\u00a0<\/i>The chemistry of polymer. 4<sup>th<\/sup> Cambridge, UK: RSC publishing. 2012.<\/li>\n<li>Mark J. E. Physical properties of polymer. Handbook 2<sup>nd<\/sup> New York, USA: springer science +business media LLC. 2007.<\/li>\n<li>SAKO T., ITO A and YAMAGUCHI M.\u00a0 Surface segregation during injection molding of polycarbonate\/ poly(methyl methacrylate) blend. <em> Polym. Res.<\/em>\u00a02017;24(89):86-90.<\/li>\n<li>Dixt M., Mathur V., Gupta S., Baboo M., Sharma K and Saxena N. S. Morphology, miscibility and mechanical properties of PMMA\/ PC blend. <em>Multinational journal.\u00a0<\/em>2010;82(12):866-878.<\/li>\n<li>Tjernlund J. A., Gamstedt E. K and Xu Z. H. Influence of molecular weight on strain-gradient yielding in polystyrene. <em> Eng. Sci.\u00a0<\/em>2004;44(10):1987-1997.<br \/>\n<a href=\"https:\/\/doi.org\/10.1002\/pen.20202\" target=\"_blank\">CrossRef<\/a><\/li>\n<li>Briscoe B. J., Fiori L and Pelillo E. Nano-indentation of polymeric surfaces. <em> Phys. D<\/em>: <em>Appl. Phys<\/em>. 1998;31(19):2395\u20132405.<br \/>\n<a href=\"https:\/\/doi.org\/10.1088\/0022-3727\/31\/19\/006\" target=\"_blank\">CrossRef<\/a><\/li>\n<li>Sperling L. H.\u00a0<em>\u00a0<\/em>Introduction to Physical Polymer Science. New York: US, John Wiley &amp; Sons. 1993.<\/li>\n<li>Zhong Z. W., Wang Z. F., Zirajutheen B. M. P. Tan Y. S and Tan Y. H.\u00a0 Polishing of poly(methyl methacrylate), polycarbonate, and SU-8 polymers. <em> Sci-Poland<\/em>. 2007;25(1):103-112.<\/li>\n<li>Stanek M., Manas D., Manas M and Senkerik V.\u00a0 How surface roughness influence the polymer flow. <em>recent advances in mechanical engineering and mechanics.<\/em>\u00a02014;134-138.<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>Introduction The recent few years\u2019 have revealed huge developments in  [&#8230;]<\/p>\n","protected":false},"author":9,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[61],"tags":[],"class_list":["post-24663","post","type-post","status-publish","format-standard","hentry","category-vol11no4"],"_links":{"self":[{"href":"https:\/\/biomedpharmajournal.org\/staging\/wp-json\/wp\/v2\/posts\/24663","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/biomedpharmajournal.org\/staging\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/biomedpharmajournal.org\/staging\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/biomedpharmajournal.org\/staging\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/biomedpharmajournal.org\/staging\/wp-json\/wp\/v2\/comments?post=24663"}],"version-history":[{"count":6,"href":"https:\/\/biomedpharmajournal.org\/staging\/wp-json\/wp\/v2\/posts\/24663\/revisions"}],"predecessor-version":[{"id":32603,"href":"https:\/\/biomedpharmajournal.org\/staging\/wp-json\/wp\/v2\/posts\/24663\/revisions\/32603"}],"wp:attachment":[{"href":"https:\/\/biomedpharmajournal.org\/staging\/wp-json\/wp\/v2\/media?parent=24663"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/biomedpharmajournal.org\/staging\/wp-json\/wp\/v2\/categories?post=24663"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/biomedpharmajournal.org\/staging\/wp-json\/wp\/v2\/tags?post=24663"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}